Article details
In accordance with DIN standardConnection to customer-specific hotel management software possibleConnecting to Room Management Systems possible (e.g. room light and welcoming light)Suitable for state-of-the-art OT structures (e.g. browser-based authorisation control for keys and personnel, thin client, cross-location server management...)Fast updating of access authorisations for guest room doors (online + mesh network for example)Version: Battery-operated, intelligent door terminal, touchless activation with Dialock key or alternatively with mobile key. Thumbturn on the inside which displays ‘Do not disturb’ on the outside when locked. Locking in mechanical. The door can be opened without a key at any time from the insideTransponder technology: Mifare ClassicDegree of protection: IP20Standard: Tested for fire resistance in accordance with EN 1634EN 1906 (terminal)EN 179 (with suitable and appropriate lever handle shape)Voltage supply: 4 x 1.5 V AA
Product typeDoor terminal set
Area of applicationInterior doors (hotel guest doors)
Distance72 mm
Door thickness35 – 95 mm
Area of application
for guest room interior doors,with approval for use as fire resistant door and smoke control door
Transponder technology
Tag-it™-ISO®, Mifare DESfire EV2, Mifare Classic EV1
Functionality
battery-operated, intelligent door terminal, can be activated contactlessly using Dialock key (passive transponder)- Red/white LEDs/Piezo signal generator for indication of locking and unlocking- Door backplate interior module with rotary knob with which 'Do not disturb' can be indicated on the exterior module by a flashing signal (rotary knob = DND = 'Do not disturb' function). Mechanical locking takes place using the thumbturn and pushes the deadbolt of the mortice lock forward- The door can be opened from the inside without a key at any time by operating the lever handle- several keys per room and up to 20 keys per door terminal are possible- mechanical emergency opening is possible- with real-time clock for logging all procedures, housing openings, emergency openings and battery removals (memory for up to 1000 log entries, for up to 1000 user keys)- Tamper protection switch on interior module blocks the door terminal if the internal backplate is removed. Access from the outside is blocked for user keys if the tamper protection switch has been activated. The tamper protection switch can be optionally activated- for service personnel: Indication of need for battery change
Material
Stainless steel
Order reference
Order referenceThe following components must also be ordered for a fully operational unit:1 Mortice lock for DT 700 / DT 7101 Profile cylinder for mechanical emergency opening4 Batteries AA1 Angled striking plate, only for mortice locks with 20 mm forendMounting tool special bit or SW3 screwdriver for screw with security pinMounting set (threaded screws and square spindle)If an escape route door in compliance with EN 179 is required, only the use of door terminals with U-shaped lever handle aperture parts is permitted.
Supplied with
1 exterior module with fixed lever handle aperture part1 interior module with thumbturn and fixed lever handle aperture part
Technical data attributes
1750
Additional information attributes
Notes on operation and installationPlanning by Dialock specialist is required.DT 700 door terminal modules on fire resistant and smoke control doors must be installed by Dialock specialists after approval by the door manufacturer. Otherwise the Fire and Smoke Control Certificate for the door will be invalidated.Only to be used in combination with DIN mortice lock for DT 700. The comfort function is set via the mortice lock.If an escape route door in accordance with EN 179 is required, only door terminals with U-shaped lever handle aperture parts are permitted.Mechanical emergency openingThe DT 700 door terminal set must always be equipped with a profile cylinder to make mechanical emergency opening possible. The installation of a profile cylinder with fire resistance approval is mandatory for approval as a fire resistant or smoke control door. When using mechanical emergency opening, please note the information sheet for determining the length of the single profile cylinder.The batteries in the door backplate interior module are secured in the covering with a special screw. This is intended to prevent unauthorised battery removal. For this reason, a special bit is required to equip the interior module with batteries, which must be ordered separately.
In accordance with DIN standardConnection to customer-specific hotel management software possibleConnecting to Room Management Systems possible (e.g. room light and welcoming light)Suitable for state-of-the-art OT structures (e.g. browser-based authorisation control for keys and personnel, thin client, cross-location server management...)Fast updating of access authorisations for guest room doors (online + mesh network for example)Version: Battery-operated, intelligent door terminal, touchless activation with Dialock key or alternatively with mobile key. Thumbturn on the inside which displays ‘Do not disturb’ on the outside when locked. Locking in mechanical. The door can be opened without a key at any time from the insideTransponder technology: Mifare ClassicDegree of protection: IP20Standard: Tested for fire resistance in accordance with EN 1634EN 1906 (terminal)EN 179 (with suitable and appropriate lever handle shape)Voltage supply: 4 x 1.5 V AA
Product typeDoor terminal set
Area of applicationInterior doors (hotel guest doors)
Distance72 mm
Door thickness35 – 95 mm
Area of application
for guest room interior doors,with approval for use as fire resistant door and smoke control door
Transponder technology
Tag-it™-ISO®, Mifare DESfire EV2, Mifare Classic EV1
Functionality
battery-operated, intelligent door terminal, can be activated contactlessly using Dialock key (passive transponder)- Red/white LEDs/Piezo signal generator for indication of locking and unlocking- Door backplate interior module with rotary knob with which 'Do not disturb' can be indicated on the exterior module by a flashing signal (rotary knob = DND = 'Do not disturb' function). Mechanical locking takes place using the thumbturn and pushes the deadbolt of the mortice lock forward- The door can be opened from the inside without a key at any time by operating the lever handle- several keys per room and up to 20 keys per door terminal are possible- mechanical emergency opening is possible- with real-time clock for logging all procedures, housing openings, emergency openings and battery removals (memory for up to 1000 log entries, for up to 1000 user keys)- Tamper protection switch on interior module blocks the door terminal if the internal backplate is removed. Access from the outside is blocked for user keys if the tamper protection switch has been activated. The tamper protection switch can be optionally activated- for service personnel: Indication of need for battery change
Material
Stainless steel
Order reference
Order referenceThe following components must also be ordered for a fully operational unit:1 Mortice lock for DT 700 / DT 7101 Profile cylinder for mechanical emergency opening4 Batteries AA1 Angled striking plate, only for mortice locks with 20 mm forendMounting tool special bit or SW3 screwdriver for screw with security pinMounting set (threaded screws and square spindle)If an escape route door in compliance with EN 179 is required, only the use of door terminals with U-shaped lever handle aperture parts is permitted.
Supplied with
1 exterior module with fixed lever handle aperture part1 interior module with thumbturn and fixed lever handle aperture part
Technical data attributes
1750
Additional information attributes
Notes on operation and installationPlanning by Dialock specialist is required.DT 700 door terminal modules on fire resistant and smoke control doors must be installed by Dialock specialists after approval by the door manufacturer. Otherwise the Fire and Smoke Control Certificate for the door will be invalidated.Only to be used in combination with DIN mortice lock for DT 700. The comfort function is set via the mortice lock.If an escape route door in accordance with EN 179 is required, only door terminals with U-shaped lever handle aperture parts are permitted.Mechanical emergency openingThe DT 700 door terminal set must always be equipped with a profile cylinder to make mechanical emergency opening possible. The installation of a profile cylinder with fire resistance approval is mandatory for approval as a fire resistant or smoke control door. When using mechanical emergency opening, please note the information sheet for determining the length of the single profile cylinder.The batteries in the door backplate interior module are secured in the covering with a special screw. This is intended to prevent unauthorised battery removal. For this reason, a special bit is required to equip the interior module with batteries, which must be ordered separately.